Production of thermoelectric modules
  • russian
  • english
  • french
  • spain
  • porto
  • italian
  • home
  • mail
  • map
Rambler's Top100

LCB series thermoelectric modules

LCB series thermoelectric modules

 

Designs of LCB series thermoelectric modules

System of notation:
An universal abbreviation is used to notate thermoelectric coolers: LCB-N-C-h, where:
LCB — series notation: low-cost thermoelectric battery for mass consumption;
N — number of thermocouples in the cooler;
С — length of the rib of the thermoelectric element basis (in millimeters);
h — height of the thermoelectric element (in millimeters). 
For example, in the module LCB-127-1,0-1,3: 127 thermoelectric couples (256 thermoelectric elements), every element has the cross-section of 1,0x1,0 mm and is 1,3 mm high.

STANDARD TERMS OF DELIVERY

ADDITIONAL OPTIONS

Please do not hesitate to contact us if you have any further questions.
Phone:+7 (812) 394 13 10, E-mail: info@kryotherm.ru

Parameters Imax, Qmax, Umax, dTmax - are given at Th=300K.

NameImax
(A)
Qmax
(W)
Umax
(V)
dTmax
(K)
R
(Ohm)
A
(mm)
B
(mm)
C
(mm)
D
(mm)
H
(mm)
Design
LCB-127-1,0-1,3 3,6 36,0 16,1 71 3,20 30,0 30,0 30,0 30,0 3,6 1
LCB-127-1,4-1,5 6,1 61,0 16,1 71 2,05 40,0 40,0 40,0 40,0 3,9 1
LCB-127-1,4-1,5 (2) 6,1 61,0 16,1 71 2,05 40,0 40,0 40,0 44,0 3,9 2
LCB-127-1,4-1,15 8,0 80,0 16,1 71 1,50 40,0 40,0 40,0 40,0 3,4 1
LCB-127-1,4-1,15 (2) 8,0 80,0 16,1 71 1,50 40,0 40,0 40,0 44,0 3,4 2
LCB-127-1,0-0,8 5,8 56,0 15,7 69 2,00 40,0 40,0 40,0 40,0 3,2 1
LCB-127-1,0-0,8 (2) 5,8 56,0 15,7 69 2,00 40,0 40,0 40,0 44,0 3,2 2
LCB-127-1,4-2,5 3,7 37,4 16,3 72 3,20 40,0 40,0 40,0 40,0 4,8 1
LCB-127-1,4-2,5 (2) 3,7 37,4 16,3 72 3,20 40,0 40,0 40,0 44,0 4,8 2

STANDARD TERMS OF DELIVERY

  • substrate material — alumina (ВК-96)
  • height tolerance ± 0,05 mm
  • paralelism 0,03 mm
  • wire length 120 mm
  • operating temperature up to 80°С (assembly solder Tm >= 139°С)

ADDITIONAL OPTIONS

DescriptionNotation (*)Note
operating temperature up to 120°C HT(120) assembly solder with Tm = 139°C 
operating temperature up to 150°C HT(150) assembly solder Pb-Sn with Tm = 183°C
sealant: epoxy or silicon coating E, S  
type and length of wires by customer’s requirement    

(*) - the notates shown are used to notate additional options in cooler name.

For example, in the module LCB-127-1,0-1,3: 127 thermoelectric couples (256 thermoelectric elements), every element has the cross-section of 1,0?1,0 mm and is 1,3 mm high.